Skip to main content
BSS/OSS Academy
All developments

Chapter 7 · Networking

NVIDIA and Cisco USFP: a denser pluggable optical module for 400 Gb/s lanes

NVIDIA · Cisco

Ultra-Dense Small Form Factor Pluggable (USFP): a new optical module format in an OSFP-sized footprint, designed for 400 Gb/s electrical lanes and up to 12.8 Tb/s per module, with an open specification promised through a multi-source project.

AnnouncedLast checked against its sources on 2 November 2026

What was announced?

NVIDIA and Cisco announced plans for the Ultra-Dense Small Form Factor Pluggable (USFP), “a high-density optical module” for AI factories that use pluggable transceivers. (The brief called it “Ultra Small”; the companies’ name is “Ultra-Dense”.) TE Connectivity and Amphenol are named as building the cages, connectors and modules, and “additional partners are expected to join”.

The companies say USFP is the first module designed for “400Gb/s-per-lane electrical signals”, with capacity “up to 12.8Tb/s”. The first planned transceivers have 16 full-duplex lanes in an “OSFP-sized footprint”, for switches and SuperNICs (the network cards in each GPU server), with a path to 32 or more lanes. The specification is to be published through an “upcoming community-led multi-source project”.

Why does it matter?

An optical transceiver turns the electrical signal from a switch chip or network card into light for the fibre, and back again. In a GPU cluster every GPU needs one or more of them, so a large cluster runs hundreds of thousands. Their size limits how much bandwidth fits on a switch’s front panel, and their power is a real share of the network’s draw.

Each step in switch-chip bandwidth needs either faster lanes or more modules. USFP doubles the electrical lane rate of today’s 200 Gb/s-per-lane modules in the same footprint, so a switch can expose four times the bandwidth per panel without giving up modules that can be pulled and replaced.

What has changed?

AspectToday’s 200 Gb/s-per-lane pluggables (e.g. 1.6T OSFP)USFP (as announced)
Electrical lane rate200 Gb/s400 Gb/s
Capacity per moduleUp to 1.6 Tb/s (8 × 200G)Up to 12.8 Tb/s
FootprintOSFPOSFP-sized
Bandwidth and front-panel densityBaseline“4x”, the companies’ claim
Power efficiencyBaseline“~1.3x” better, the companies’ claim
ServiceabilityField-replaceableField-replaceable (unchanged)

USFP is the pluggable route; co-packaged optics (see Spectrum-X Ethernet Photonics) is the other. The industry is pursuing both.

How does it work?

A pluggable module sits in a cage on the switch’s front panel. The switch chip drives electrical signals across the circuit board to the module, where a digital signal processor cleans them up and lasers and photodetectors convert them to and from light. Doubling the lane rate to 400 Gb/s makes that electrical path harder: signals degrade faster, so the connector, cage and board have to be designed for it, which is why the connector makers are part of the announcement.

More bandwidth in the same space means more heat in the same space. The companies say USFP handles up to “100 watts” of power dissipation without a dedicated embedded cooling circuit.

Figures and claims, and what backs them

  • Published specificationThe companies state up to 12.8 Tb/s per module and 400 Gb/s per electrical lane; first modules with 16 full-duplex lanes in an OSFP-sized footprint.
  • Manufacturer claimNVIDIA and Cisco claim “4x” the bandwidth and front-panel density and “~1.3x” better power efficiency than 200 Gb/s-per-lane pluggables.
  • Manufacturer claimThe companies say a module can dissipate up to 100 W without a dedicated embedded cooling circuit.

Impact on AI infrastructure delivery

Power & Cooling
Modules of up to 100 W each concentrate heat at the switch front panel; switch cooling (air or liquid) must be checked for the new density.
Networking
Higher radix per switch means fewer switches and fewer tiers for the same cluster, but a new optics generation to qualify. Until the multi-source specification exists, the network team is buying a two-vendor design, so second-source risk belongs on the risk register.
Operations
Modules stay hot-swappable, so the spares and replacement process carries over, but at much higher value per module.

Commercial availability

  1. Announced (current stage)Described publicly; no date for customers to buy it.
  2. PlannedA stated availability window that has not arrived yet.
  3. ShippingIn production and reaching early customers or partners.
  4. Generally availableOrderable by any customer through normal channels.
  5. DeployedRunning in customers’ production environments, confirmed by them or the manufacturer.

The companies “announced plans for” USFP. No availability date, product list or price has been given, and the multi-source project that will publish the specification has not yet been formed.

Not yet confirmed

  • Only NVIDIA’s copy of the joint release was read; Cisco’s own newsroom page was not found.
  • Trade press places the announcement at the OCP Global Summit; the release names no event.

Learn more in BSS/OSS Academy

Official sources

  1. NVIDIA and Cisco Introduce New Pluggable Optics Form Factor to Scale AI Factories(opens in a new tab)NVIDIA Newsroom · 12 October 2026 · Manufacturer

Figures are as the manufacturer states them unless marked otherwise. None has been independently tested by BSS/OSS Academy.